Diaphragm safety relief valve protecting closed water heaters (hot water cylinders) against overpressure per DIN 4753. The 6 bar opening pressure must not exceed the permissible working pressure of the protected water heater.
| Parameter | Value |
|---|---|
| Code | 10004724 |
| Series | Watts SVW |
| Type | Diaphragm safety relief valve for water heaters (DIN 4753) |
| Opening pressure | 6 bar |
| Inlet thread | 3/4" (internal) |
| Outlet thread | 1" (internal) |
| Max working temperature | 110 °C |
| Media | Water |
| Body material | Brass CW617N |
| Diaphragm | EPDM |
| Certification | TÜV, DIN 4753, PED 2014/68/EU |
| Installation position | Vertical, spring upwards |
The valve size is chosen according to the water heater output and volume using the manufacturer (Watts) table and DIN 4753; confirm the exact match in the Watts datasheet.
Watts manufacturer's catalogue: wattswater.eu
No. SVW series valves are factory sealed and calibrated. Any attempt to adjust voids the certification and manufacturer warranty. If a different pressure setting is required, switch to the appropriate rated model (e.g. SVW 8 = 8 bar).
Annual functional test is recommended (manual opening via lever — system pressure should recover without leaks). Replacement — when leaks are visible, seat scaling appears, or after 10-15 years of service (depending on system water quality).
Yes. The SVW series is designed for closed water heaters per DIN 4753 (Watts product description).