Hexonic FC-009-P16-2S-59H gasketed plate heat exchanger, DN50, 59 plates, PN 16

Hexonic FC-009-P16-2S-59H gasketed plate heat exchanger, DN50, 59 plates, PN 16

€ 4594,96€ 6889,00+ PVM
SKU
A3S-P16-59-H
Model
FC-009-P16-2S-59H / A3S-P16-59-H
Delivery
1 - 2 working days.
Brand
Hexonic
Connection Type
jungs_flanams_dn65_pn16_std_316l_05_mm_epdm_ht_6_connection
operating_pressure
16
Number Of Plates
59
degrees
2
Connection nozzles
6
used_for
silumokaitis_karstam_vandeniui
Weight
183.7kg.
Have questions?
TL;DR: Hexonic FC-009-P16-2S-59H — gasketed (dismountable) plate heat exchanger from the Hexonic FC-009 / A3S frame family: 59 stainless steel (316L) plates, EPDM gaskets, PN 16, DN65 flange connections. 2-pass (2S) version with 6 connections, designed for HVAC substations.
  • Application: primary/secondary loop separation — district heating, DHW, heating, cooling
  • Heat capacity: depends on flow rates, temperatures and number of plates (select with Hexonic CAIRO)
  • Nominal pressure: PN 16 (16 bar); frame design pressure up to 25 bar
  • Connection: DN65 flange connections

Where FC-009-P16-2S-59H is used

Mid-size frame for higher-capacity multi-family and commercial substations. The gasketed / framed construction allows future capacity expansion by adding plates to the same frame or cleaning off fouling without replacing the unit — important for long-term operation in multi-family and commercial substations. Plates are 316L (1.4404) stainless steel, resistant to municipal district heating water. Gaskets are EPDM (glued or clip-on depending on plate type), suitable for water up to +150 °C.

Technical specifications

Parameter Value
SKUA3S-P16-59-H
SeriesHexonic FC-009 / A3S
ModelFC-009-P16-2S-59H
ConstructionGasketed / framed — bolted plate pack with elastomer gaskets
Number of plates59
Plate profile"H" (high chevron angle — higher heat transfer coefficient)
Loop configuration2-pass (2S), 6 connections (supplier designation)
Nominal pressure (PN)16 bar (frame design up to 25 bar)
Max operating temperature+150 °C (EPDM gaskets)
ConnectionDN65 flange connections
Plate materialStainless steel 316L / 1.4404 (titanium plates available on request)
GasketsEPDM (standard); NBR or FKM/Viton available
FrameCarbon steel, powder-coated
StandardsPED 2014/68/EU

Heat transfer capacity — quick calculation

Capacity depends on flow rate, ΔT and logarithmic mean temperature difference (LMTD). General formula: P = Q × ΔT × 1.163 (P — kW, Q — m³/h, ΔT — °C).

Illustrative calculation, not this model's capacity. Example for heating mode (primary 90/70 °C → secondary 65/40 °C): at Q = 5 m³/h and effective ΔT ≈ 20 °C → P ≈ 116 kW.

Designer note: the "H" plate profile (higher chevron angle) yields a higher heat transfer coefficient but also a higher pressure drop (Δp). Before choosing the exact plate count, run a calculation via Hexonic Cairo Selection Software or request Amegata's technical consultation — we will match plate count to your flow rate, ΔT and allowable Δp budget.

When to choose FC-009-P16-2S-59H

  • Multi-family and mixed-use substations
  • Micro-district (district heating) separation for multiple buildings

B2B delivery and logistics via Amegata.lt

  • Delivery within 2-5 business days across Lithuania (made-to-order from manufacturer)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for sizing (Cairo calculations)
  • Spare gaskets and plates — can be ordered together

Hexonic manufacturer's catalogue: hexonic.com/en/products/plate-and-frame-exchangers/f/

Frequently asked questions

What does "H" mean in FC-009-P16-2S-59H?

"H" denotes a high chevron angle on the plate (high theta) — higher heat transfer coefficient but higher pressure drop. Some Hexonic frames also offer "L" (low chevron, lower Δp) or mixed packs (H+L) — we select the mix to fit your flow rate and Δp budget.

Can glycol mixtures be used?

Yes. Confirm suitability and concentration of glycol solutions with Hexonic (the manufacturer does not state them in the F-series documents). For DHW — only potable-grade fluids.

What maintenance is required?

The gasketed construction allows periodic plate cleaning (CIP or mechanical) when fouling appears. Replace gaskets when leakage or wear appears (per the manufacturer's instructions). For comparison: brazed exchangers have no gasket maintenance — but plates cannot be cleaned or added either.

When to choose gasketed vs brazed?

Gasketed — when you need the ability to clean off fouling (hard water, commercial systems), change capacity (add plates in pack) or when gasket maintenance is acceptable. Brazed — when you need low weight, compact housing and a "fit and forget" solution (without capacity expansion).

Is it suitable for regions with aggressive water?

In some Lithuanian regions, district heating water contains elevated chlorides or ammonia — 316L (standard plates) is suitable in most cases, but for very aggressive water we recommend titanium plates (available on request). For hard water with elevated Ca/Mg carbonate content, limescale gradually builds up on the plates and reduces heat-transfer efficiency; for such systems gasketed (plate-and-frame) exchangers are preferable, as they can be periodically opened for mechanical or CIP cleaning. Contact us — we will select the model best suited to your water conditions.

How much boiler-room space does it need?

This frame is approximately ~636 mm. You will need free floor space equal to the frame length on one side to loosen the tie bolts and slide out plates for maintenance. Plan this into your boiler-room layout.