-38%
Alfa Laval CB20-60H brazed plate heat exchanger, G 1", 60 plates, PN 16

Alfa Laval CB20-60H brazed plate heat exchanger, G 1", 60 plates, PN 16

€ 194,25€ 314,83+ PVM
SKU
3287000018
Model
CB20-60H
Delivery
1 - 2 working days.
Brand
Alfa Laval
used_for
silumokaitis_sildymui
Connection Type
iorsriegis_dn2525
Number Of Plates
60
Connection nozzles
4
degrees
1
Weight
6kg.
Have questions?
TL;DR: Alfa Laval CB20-60H — brazed plate heat exchanger with 60 stainless steel plates and copper brazing. Designed for multi-family building substations and small commercial systems — HVAC heating, cooling and domestic hot water (DHW).
  • Application: primary/secondary loop separation — district heating, DHW, process
  • Heat capacity: ~48-106 kW (depending on flow rate and ΔT)
  • Nominal pressure: PN 16 (16 bar)
  • Connection: G 1" external thread (both sides)

Where CB20-60H is used

This 60-plate brazed heat exchanger with a "H" (High theta) profile — high chevron angle — better heat transfer, higher Δp. The CB20 series comprises compact, hermetic units that reliably separate primary and secondary loops in multi-family building substations and small commercial systems. The brazed gasket-free construction requires no periodic maintenance that gasketed exchangers would need — this reduces operating costs across the equipment lifecycle.

Technical specifications

Parameter Value
Code3287000018
SeriesAlfa Laval CB20
ModelCB20-60H
Number of plates60
Chevron profileH (High theta)
Nominal pressure (PN)16 bar
Max. temperature225 °C
ConnectionG 1" external thread (S1-S4)
Plate materialStainless steel
Brazing fillerCopper
Approx. dimensions (L × W × H)126 × 94 × 324 mm
Weight~6 kg
ConstructionBrazed, hermetic (gasket-free)
MediaWater, glycol solutions, other media compatible with stainless steel and copper

Heat transfer capacity — quick calculation

Capacity depends on flow rate, ΔT and logarithmic mean temperature difference (LMTD). General formula: P = Q × ΔT × 1.163 (kW, Q m³/h, ΔT °C).

Example for heating mode (primary 90/70 °C → secondary 65/40 °C): at Q = 2 m³/h and effective ΔT ≈ 20 °C → P ≈ 47 kW. With Q = 3 m³/h and ΔT ≈ 25 °C → P ≈ 87 kW.

Designer note: the "H" (High theta) plate profile — higher chevron angle, higher heat transfer coefficient and higher pressure drop. Best for higher temperature regimes with lower flow rates. Before final sizing, run a calculation via Alfa Laval CAS (Calculation and Selection Software) or request our technical consultation — we will verify actual Δp for your flow rate.

When to choose CB20-60H

  • Systems with capacity demand ~48-106 kW (depending on temperature program)
  • Primary/secondary loop separation in multi-family building substations and small commercial systems
  • Domestic hot water (DHW) heat exchanger
  • Cooling system buffer separation (primary chilled water / secondary building loop)
  • When a compact solution without gasket maintenance is required

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across Lithuania (from our warehouse in Vilnius)
  • Delivery across the EU on request
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for sizing selection

Official Alfa Laval catalogue: alfalaval.com/CB20

Frequently asked questions

What does "H" mean in CB20-60H?

"H" (High theta) — higher chevron angle, higher heat transfer coefficient and higher pressure drop. Best for higher temperature regimes with lower flow rates.

Can glycol mixtures be used?

Yes. CB20 series exchangers are compatible with ethylene glycol and propylene glycol solutions up to 50 %, when appropriate inhibitors are used. For DHW — only potable-grade fluids allowed.

What maintenance is required?

Brazed gasket-free construction requires no periodic disassembly maintenance. Recommended only CIP (Clean-in-Place) flushing every 3-5 years if fouling signs appear (rising pressure drop or falling heat transfer).

Is it suitable for potable water?

Yes. Stainless steel plates and copper brazing meet potable water system requirements (WRAS, DVGW and similar certifications, depending on country).

Is it suitable for regions with aggressive water?

In some regions, district heating water contains elevated chlorides or ammonia — in such systems, copper brazing may shorten the exchanger's service life. In these cases we recommend the Alfa Laval AlfaNova series (stainless steel brazing, copper-free). For hard water with elevated Ca/Mg carbonate content, limescale gradually builds up on the plates and reduces heat-transfer efficiency; for such systems gasketed (plate-and-frame) exchangers are preferable, as they can be periodically opened for mechanical or CIP cleaning. Contact us — we will select the model best suited to your water conditions.

How to choose the right plate count?

Plate count is determined by required capacity, flow rates and allowable pressure drop. The same CB20 series with different plate counts covers different capacity classes — from small user branches to large primary loops. Contact us — we will provide a specific selection based on your project data.