Hexonic LB60-50-5/4 brazed plate heat exchanger, 5/4", 50 plates, PN 30

Hexonic LB60-50-5/4 brazed plate heat exchanger, 5/4", 50 plates, PN 30

€ 585,60€ 960,00+ PVM
SKU
0205-0095
Model
LB60-50-5/4
Delivery
1 - 2 working days.
Brand
Hexonic
used_for
silumokaitis_sildymui
Connection Type
iorsriegis_dn32
Number Of Plates
50
assembly_length
128
Connection nozzles
4
degrees
1
operating_pressure
30
Weight
13kg.
Have questions?
TL;DR: Hexonic LB60-50-5/4 — brazed plate heat exchanger with 50 stainless steel AISI 316L plates and copper brazing. LB60 series, single-pass (1-pass) construction with G 5/4" (1-1/4") external threads. Designed for HVAC heating, cooling and domestic hot water (DHW) production.
  • Application: primary/secondary loop separation — district heating, DHW, process
  • Nominal pressure: PN 30 (30 bar)
  • Connection: G 5/4" (1-1/4") external thread (both sides)

Where LB60 LB60-50-5/4 is used

The 50-plate Hexonic LB60 exchanger is typically selected for: medium-to-large capacity heat substations, cooling systems primary/secondary loop separation, process heat recovery, solar and geothermal system separation. The brazed gasket-free construction requires no periodic disassembly maintenance that gasketed exchangers would need. The compact housing (plate 538 × 123 mm, depth 128.5 mm) fits even in small technical rooms.

Technical specifications

ParameterValue
Code0205-0095
SeriesHexonic LB60
ModelLB60-50-5/4
Number of plates50
Plate profileStandard
Passes1 (1-pass, 4 connections)
Nominal pressure (PN)30 bar
Max working temperature230 °C
Min working temperature-195 °C
ConnectionG 5/4" (1-1/4") external thread (K1-K4)
Plate materialStainless steel AISI 316L (1.4404)
Brazing fillerCopper (Cu)
Plate dimensions538 × 123 mm
Unit depth (F)~128.5 mm (formula: 11 + 2.35 × N, N = 50)
Weight~13 kg
ConstructionBrazed, hermetic (gasket-free)
MediaWater, inhibited propylene and ethylene glycol solutions at standard concentrations; other media — consult the manufacturer

Heat transfer capacity — quick calculation

Capacity depends on flow rate, ΔT and logarithmic mean temperature difference (LMTD). General formula: P = Q × ΔT × 1.163 (kW, Q m³/h, ΔT °C).

Illustrative calculation, not this model's capacity. Example for heating mode (primary 90/70 °C → secondary 65/40 °C): at Q ≈ 9.1 m³/h and effective ΔT ≈ 20 °C → P ≈ 212 kW. With higher flow and wider ΔT, capacity scales linearly up to the plate area limit.

Designer note: Standard plate profile — balanced heat transfer and pressure drop. At higher flow rates the pressure drop (Δp) grows non-linearly — before final sizing, run a calculation via Hexonic CAIRO Selection Software or request our technical consultation.

When to choose LB60-50-5/4

  • When a compact, gasket-free hermetic construction is preferred
  • When the working media are water or inhibited glycol mixtures
  • When budget constraints favor brazed over gasketed, and service conditions allow copper brazing

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across Lithuania (from our warehouse in Vilnius)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for sizing selection

Frequently asked questions

What does "H/L/M" mean in Hexonic model codes?

Standard (no "H") plate profile — balanced heat transfer and pressure drop, suited for typical heating/cooling applications.

Can glycol mixtures be used?

Yes. Hexonic LB60 series is compatible with ethylene glycol and propylene glycol solutions at standard concentrations, when appropriate inhibitors are used. For DHW — only potable-grade fluids allowed.

What maintenance is required?

Brazed gasket-free construction requires no periodic disassembly maintenance. Recommended only CIP (Clean-in-Place) flushing periodically if fouling signs appear (rising pressure drop or falling heat transfer).

Is it suitable for potable water?

Not in all cases. Hexonic states that the standard copper-brazed L series should not be treated as a universally suitable solution for direct contact with potable water — acceptability depends on local requirements and approvals. For potable water Hexonic recommends SafePLATE (double-wall design) or the all-stainless-steel LUNA series.

Is it suitable for regions with aggressive water?

In some regions, district heating water contains elevated chlorides or ammonia — in such systems, copper brazing may shorten service life. In these cases we recommend the Danfoss XB CoResist series or gasketed plate exchangers with EPDM/NBR gaskets. For hard water with elevated Ca/Mg carbonate content, limescale gradually builds up on the plates and reduces heat-transfer efficiency; for such systems gasketed (plate-and-frame) exchangers are preferable, as they can be periodically opened for mechanical or CIP cleaning. Contact us — we will select the model best suited to your water conditions.

Is insulation needed?

In heating systems where heat losses to the room should be minimized, the APFI series insulation shell is recommended (polyurethane foam with aluminum cover, up to 135 °C). In substations, insulation is nearly a default choice.

  • About us

  • HELP AND INFORMATION

  • CONNECT WITH US

Notify me of new products
By clicking the "Subscribe" button, you agree to the Privacy Policy. You will always find a link in the newsletter that you can click to unsubscribe from.

@ 2024-2026. All rights reserved.

    Solution: e-bros