-39%
Hexonic LB31-90H-2S-5/4 brazed plate heat exchanger, 90 plates, PN 30

Hexonic LB31-90H-2S-5/4 brazed plate heat exchanger, 90 plates, PN 30

€ 646,60€ 1060,00+ PVM
SKU
0203-0720
Model
LB31-90H-2S-5/4
Delivery
1 - 2 working days.
Brand
Hexonic
used_for
silumokaitis_karstam_vandeniui
Connection Type
iorsriegis_dn32
Number Of Plates
90
assembly_length
222
Connection nozzles
6
degrees
2
operating_pressure
30
Weight
12.1kg.
Have questions?
TL;DR: Hexonic LB31-90H-2S-5/4 — compact LB31 series brazed plate heat exchanger with 90 stainless steel (AISI 316L) plates, copper brazing and 2-pass (2S) configuration. Designed for HVAC heating, cooling and domestic hot water (DHW) production.
  • Application: heating/cooling/DHW primary–secondary loop separation
  • Nominal pressure: PN 30 (3.0 MPa)
  • Connection: G 1¼" (5/4) external thread (both sides)

Where LB31-90H is used

This 90-plate brazed heat exchanger with H (high) chevron angle and 2-pass (2S) configuration is typically chosen for domestic hot water (DHW) primary circuits in multi-family substations (primary side — district heating network, secondary side — DHW). The 2-pass configuration with 6 connections efficiently maintains the logarithmic mean temperature difference (LMTD) under asymmetric DHW loads (e.g., 70/40 °C → 10/55 °C). The compact housing (123 × 286 mm base × height) fits even in tight technical rooms.

Technical specifications

Parameter Value
Code0203-0720
SeriesHexonic LB31
ModelLB31-90H-2S-5/4
Number of plates90
Configuration2-pass (2S), 6 connections
Nominal pressure (PN)30 bar (3.0 MPa)
ConnectionG 1¼" (5/4) external thread
Plate materialStainless steel AISI 316L
Brazing materialCopper
Working temperature range−195 °C … +230 °C
Dimensions (W × D × H)123 × 221.5 × 286 mm (W × D × H)
Weight (approx.)~11.86 kg
ConstructionVacuum-furnace brazed, hermetic (gasket-free)
MediaWater, inhibited propylene and ethylene glycol solutions at standard concentrations; other media — consult the manufacturer

Heat transfer capacity — quick calculation

Capacity depends on flow rate, ΔT and logarithmic mean temperature difference (LMTD). General formula: P = Q × ΔT × 1.163 (kW, where Q — m³/h, ΔT — °C).

Illustrative calculation, not this model's capacity. Example for typical heating duty (primary 90/70 °C → secondary 65/40 °C): at Q = 2.9 m³/h and effective ΔT ≈ 25 °C → P ≈ 85 kW.

Designer note: the "H" profile delivers a higher heat transfer coefficient but also higher pressure drop. Before final sizing, run a calculation via Hexonic CAIRO Selection Software or request Amegata technical consultation — we will select the right model based on your flow rates and ΔT.

When to choose LB31-90H

  • Domestic hot water (DHW) primary heat exchanger with 2-pass LMTD optimization
  • Cooling systems buffer separation (chilled water primary / building loop secondary)
  • When gasket-free hermetic construction is required
  • Water and glycol systems with appropriate inhibitors

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across Lithuania (from our warehouse in Vilnius)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for sizing and CAIRO calculation

Frequently asked questions

What is the difference between "H", "L" and standard plate profiles?

The letter denotes the plate chevron angle: "H" — high angle (higher heat transfer coefficient, higher pressure drop), (no letter — standard profile), "L" — low (lower Δp, suits higher flow rates).

Is it suitable for ethylene glycol and propylene glycol solutions?

Yes. Hexonic L-series copper-brazed exchangers are compatible with ethylene glycol and propylene glycol solutions at standard concentrations, when appropriate inhibitors are used. For DHW systems, only potable-grade fluids are allowed.

What maintenance is required?

Brazed gasket-free construction requires no periodic disassembly maintenance. Recommended only CIP (Clean-in-Place) flushing periodically if fouling signs appear (rising pressure drop or falling heat transfer). Use only manufacturer-approved alkaline and acid cleaning agents; mechanical cleaning (brushes, scrapers) and chlorinated agents must not be used.g., citric, sulfamic acid) followed by neutralization and rinsing.

Is it suitable for potable water (DHW)?

Not in all cases. Hexonic states that the standard copper-brazed L series should not be treated as a universally suitable solution for direct contact with potable water — acceptability depends on local requirements and approvals. For potable water Hexonic recommends SafePLATE (double-wall design) or the all-stainless-steel LUNA series.

Is it suitable for aggressive water with chlorides or ammonia?

In some regions, district-heating water contains elevated chlorides or ammonia — in such systems, copper brazing may shorten the service life of the exchanger. In these cases we recommend the Danfoss XB CoResist series. For hard water with elevated Ca/Mg carbonate content, limescale gradually builds up on the plates and reduces heat-transfer efficiency; for such systems gasketed (plate-and-frame) exchangers are preferable, as they can be periodically opened for mechanical or CIP cleaning. Contact us — we will select the model best suited to your water conditions.

  • About us