TL;DR: IMI TA Hydronics 1.5 m capillary tube — required accessory for the DA-616 automatic differential pressure (Δp) controller. Transmits the pressure signal from the consumer branch to the regulator diaphragm; without it, Δp regulation does not work.
  • Purpose: hydraulic pressure signal transmission to the DA-616 diaphragm
  • Length: 1.5 m — standard, suits most installation cases
  • Compatibility: full DA-616 series (DN15, DN20, DN25, DN32)

Where the capillary tube is used

The DA-616 differential pressure controller operates hydraulically — it requires two pressure signals: from the beginning of the consumer branch (high-pressure side) and the end (low-pressure side). This signal is transmitted through the capillary tube, which connects the regulator diaphragm to the controlled branch point. Without the capillary tube, DA-616 will not function as a Δp regulator — it stays a plain flow valve.

Technical specifications

Parameter Value
Code52-850-915
SeriesIMI TA Hydronics
TypeCapillary (impulse) tube for Δp regulators
Length1.5 m
MaterialCopper tube (verify in IMI catalogue)
CompatibilityDA-616 series (DN15, DN20, DN25, DN32)
ConnectionIMI standard capillary fitting
Temperature rangeMatches DA-616 (up to 120 °C)
Designer note: although the capillary tube looks simple, its correct installation is critical for DA-616 operation. Avoid sharp bends (below R=50 mm), route without tension, seal fittings per IMI instructions. A leak means the regulator "does not see" the pressure signal, resulting in unstable control.

When to choose this accessory

  • Ordering a new DA-616 regulator — the accessory is not included in the valve pack
  • Replacing an old capillary (fracture, seal failure, corrosion)
  • System reconfiguration when the regulator position must move

If a longer capillary is required (1.5 m insufficient) — contact us, we will supply the alternative length available in the IMI catalogue (2 m, 3 m or similar).

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across the EU (from our warehouse in Vilnius)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation on regulator and accessory kits

Official IMI Hydronic catalogue: imi-hydronic.com

Frequently asked questions

Can an old capillary tube from another regulator be reused?

Technically — sometimes yes, if the system matches and threads are identical. In practice — not recommended: an old tube may have corrosion, deformations or leaks that compromise Δp control accuracy.

What happens if the capillary tube blocks?

DA-616 stops "seeing" the pressure signal — either fully (spring closes fully) or partially (oscillation). Symptoms: the heating branch is too hot / too cold, or temperature keeps changing. Fix — check capillary integrity and flow, replace if needed.

Does the capillary tube carry pressure?

Yes, the capillary transmits working pressure (up to 16 bar) but with no flow. Simpler than a flow pipe — but still requires PN 16 class sealing.

Can it be used with other manufacturers' Δp regulators?

No. The capillary tube is specifically designed for IMI TA Hydronics DA-616 connections. Other regulators (e.g. Danfoss AVP, Sauter, Oventrop) require the manufacturer's own original accessories.