TL;DR: IMI TA Hydronics DA-616 DN20 Kvs 8 — automatic differential pressure (Δp) controller for medium-load heating/cooling branches. Maintains a set constant Δp across the consumer branch without electrical control, providing stable operation for thermostatic and zone valves.
  • Application: constant Δp on medium-load heating risers
  • DN: 20 — mid-range DA-616 size
  • Kvs: 8 m³/h — suits ~40-90 kW heating load
  • Autonomy: hydraulic operation, no electrics

Where DA-616 DN20 Kvs 8 is used

Standard variant for medium-load risers in multi-family buildings (3-5 storeys), apartment metering schemes with higher loads, small commercial substation consumer branches. DA-616 DN20 ensures thermostatic valves react to consumer demand, not to system fluctuations caused by other users' behaviour.

Technical specifications

Parameter Value
Code52-861-020
SeriesIMI TA Hydronics DA-616
TypeAutomatic differential pressure (Δp) controller
DN20
Kvs8 m³/h
Nominal pressure (PN)16 bar (verify in IMI catalogue)
Δp setting rangePer variant — see IMI documentation
ConnectionInternal thread (Rp)
Temperature range-10 → +120 °C
MediaHeating/cooling water, glycol up to 50 %
Body materialDZR brass / bronze (per IMI documentation)
Capillary tubeOrdered separately (52-850-915 or equivalent)

Capacity — quick calculation

Water flow: Q = Kvs × √Δp. Heat capacity: P = Q × ΔT × 1.163.

Example: setting Δp = 0.3 bar (30 kPa) → Q = 8 × √0.3 ≈ 4.38 m³/h. With ΔT = 20 °C → P ≈ 102 kW.

Designer note: DA-616 DN20 Kvs 8 is the most commonly chosen variant for small-to-medium loads in multi-family buildings. Authority β ≥ 0.5 must be ensured with a Δp setpoint that exceeds 40 % of the controlled branch's pressure drop. In practice 15-25 kPa suits most apartment metering scenarios.

When to choose DA-616 DN20 Kvs 8 over DN15 Kvs 5

  • Medium-load heating risers with capacity 40-90 kW
  • Multi-family buildings (3-5 storeys) with combined branch load
  • Apartment metering schemes with larger apartment loads (>100 m²)
  • When reserve for future growth is required — DN20 leaves more room

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across the EU (from our warehouse in Vilnius)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for valve sizing

Official IMI Hydronic catalogue: imi-hydronic.com

Frequently asked questions

Is a companion flow limiter valve required?

DA-616 is a Δp controller. In some layouts it is paired with a flow-limiting valve (e.g. STAD or PICV series) — the pair guarantees both a constant Δp and a specific maximum flow.

How can I check that the valve operates correctly?

Using the capillary tube T-tappings, Δp across the consumer branch can be measured. If Δp stays stable regardless of thermostatic head positions (while other consumers change flow in the system) — the controller works correctly.

Can it be used in cooling systems?

Yes. DA-616 suits both heating (up to 120 °C) and cooling (down to -10 °C). In cooling mode ensure proper insulation to prevent diaphragm frosting from condensate.

Why does Δp fluctuate more than expected?

Common causes: (1) blocked capillary tube (clean/replace), (2) oversized Kvs (authority too low — β > 0.5 needed), (3) system air pockets (vent), (4) debris on valve seat (clean, add strainer upstream).