-38%
Danfoss XB 12L-2 40/40 brazed plate heat exchanger, PN 25
Danfoss XB 12L-2 40/40 brazed plate heat exchanger, PN 25

Danfoss XB 12L-2 40/40 brazed plate heat exchanger, PN 25

€ 684,87€ 1110,00+ PVM
SKU
004H7614
Model
XB 12L-2 40/40
Delivery
Contact for delivery term
Brand
Danfoss
used_for
silumokaitis_karstam_vandeniui
Connection Type
iorsriegis_dn25
Old Type
xb102
min_temp
10
max_temp
180
Connection nozzles
6
degrees
2
product_analogue
lb3180h2s
Weight
7.48kg.
TL;DR: Danfoss XB 12L-2 40/40 — brazed plate heat exchanger with 40 plates. DN 32, PN 25, suitable for district heating and domestic hot water (DHW) systems.
  • Code: 004H7614
  • Series: Danfoss XB-2
  • Model: XB 12L-2 40/40
  • Number of plates: 40

Where XB 12L-2 40/40 is used

This 40-plate brazed heat exchanger is designed for user branches in substations of multi-family and commercial buildings. Primary side from district heating network, secondary side for space heating or DHW production. Brazed gasket-free construction requires no periodic maintenance.

Technical specifications

Parameter Value
Code004H7614
SeriesDanfoss XB-2
ModelXB 12L-2 40/40
Number of plates40
Nominal pressure (PN)25 bar
Connection (ISO 228/1)G 1 1/4" external thread, DN 32
Plate materialStainless steel AISI 316L (1.4404)
Brazing fillerCopper brazing
Heat capacity~28-80 kW (depends on flow and ΔT)
Temperature range−196 °C … +180 °C
MediaDistrict heating water; glycol up to 50%; pH 7-10
Weight~12.5 kg
Height (without supports)~460 mm
PED categoryPED 2014/68/EU, category II
Configuration2-pass

Heat capacity — quick calculation

Formula: P = Q × ΔT × 1.163 (kW, Q m³/h, ΔT °C).

Example: heating mode (90/70 °C → 65/40 °C) at Q = 2.4 m³/h and ΔT ≈ 20 °C → P ≈ 55 kW.

Designer note: Before final XB 12L-2 40/40 selection use Danfoss HEXact sizing software — exact capacity depends on plate geometry, media properties and system load profile.

When to choose XB 12L-2 40/40

  • Substation user branches with capacity demand 28-80 kW
  • DHW primary heat exchanger for multi-family systems
  • When PED cat II certification is required for commercial buildings
  • Modernisation from outdated gasketed heat exchangers

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across Lithuania (from our warehouse in Vilnius)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for XB 12L-2 40/40 selection

Official Danfoss catalogue: store.danfoss.com/004H7614

Frequently asked questions

How does XB 12L-2 differ from XB 12L-2 CoResist?

Standard version with copper brazing — cheaper, suitable for standard district heating water (pH 7-10). For aggressive water systems — choose CoResist.

Is it suitable for potable water (DHW)?

Yes. Stainless steel plates and copper brazing meet potable water system requirements (WRAS, DVGW, depending on country).

What maintenance is required?

Brazed gasket-free construction requires no periodic disassembly. Only CIP (Clean-in-Place) flushing every 3-5 years is recommended, if fouling signs appear.

Can glycol mixtures be used?

Yes, ethylene glycol or propylene glycol solutions up to 50%, with appropriate inhibitors. For DHW — only potable-grade fluids.

What are the PED requirements?

XB series complies with PED 2014/68/EU, category II (medium risk level) — allowing commercial use in Europe.