Hexonic RHB60-40H brazed plate heat exchanger for heat pumps, 40 plates

Hexonic RHB60-40H brazed plate heat exchanger for heat pumps, 40 plates

€ 910,00+ PVM
SKU
0246-0192
Model
RHB60-40H
Delivery
1 - 2 working days.
Brand
Hexonic
used_for
silumokaitis_sildymui
Connection Type
2_x_iorsriegis_dn25__2_x_lituojamas_id_224_mm
Number Of Plates
40
Connection nozzles
4
degrees
1
product_analogue
cbh6040hf
operating_pressure
45
Weight
13.5kg.
Have questions?
TL;DR: Hexonic RHB60-40H — brazed plate heat exchanger for heat pumps. Designed for refrigerant (condenser or evaporator duty) and water/glycol on the second side. 40 stainless steel AISI 316L plates, copper brazing. PN 45 bar refrigerant side, PN 25 bar water side.
  • Application: heat pump — refrigerant ↔ water/glycol (condenser, evaporator)
  • Heat capacity: depends on refrigerant type, evaporation/condensation temperatures and mode (select with Hexonic CAIRO)
  • Nominal pressure: 45 bar refrigerant / 25 bar water
  • Connection: welded connections on refrigerant side, threaded on water side

Where RHB60-40H is used

The Hexonic R series (B60 size) is designed to separate heat pump primary and secondary loops: one side — refrigerant (R32, R410A, R454B, R290, etc.), the other — water or glycol. Used as a condenser (heating mode) or evaporator (cooling mode). The RDS (Refrigerant Distribution System) special channel pattern ensures uniform refrigerant distribution and stable superheat.

Technical specifications

ParameterValue
Code0246-0192
SeriesHexonic RHB60 (R-line)
ModelRHB60-40H
Number of plates40
Plate profileH (higher chevron angle)
Nominal pressure — refrigerant side45 bar (4.5 MPa)
Nominal pressure — water side25 bar (2.5 MPa)
Max working temperature150 °C
Min working temperature-195 °C
Connection (refrigerant)Welded connection
Connection (water/glycol)G 1" (DN25) external thread
Plate materialStainless steel AISI 316L (1.4404)
Brazing fillerCopper (Cu)
Plate dimensions538 × 125 mm
Unit depth (F)~107.0 mm
Weight~13.5 kg
Media (refrigerant)R32, R410A, R454B, R452B, R1234ze, R290 (per the Hexonic R-series catalogue)
Media (secondary side)Water, propylene glycol solutions (per the manufacturer catalogue)

Heat pump sizing guidelines

Heat pump exchanger size depends on refrigerant type, evaporation/condensation temperatures and COP. General principle: condensers need larger area (smaller ΔT between refrigerant and water); evaporators need higher Δp tolerance due to two-phase flow.

Exact sizing must be verified via Hexonic CAIRO Selection Software or manufacturer calculation based on your compressor specifications.

Designer note: RDS (Refrigerant Distribution System) plates — for evaporator duty only. Before purchasing, confirm which function (evaporator / condenser) you need RHB60-40H for — we will verify the fit for your project.

When to choose RHB60-40H

  • Heat pump condenser
  • Heat pump evaporator with matched RDS pattern
  • When refrigerant working pressure is up to 45 bar (not for CO₂ transcritical — needs a special model)
  • When a compact solution with leak-tight welded refrigerant connections is required

When to choose an alternative

  • CO₂ (R744) transcritical cycle — RHB60 not suitable (max refrigerant-side pressure 45 bar)
  • Higher capacity — larger Hexonic R-series sizes (e.g., RVC110/RCC110, RVD235/RCD235)

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across Lithuania (from our warehouse in Vilnius)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for heat pump exchanger selection

Hexonic manufacturer's catalogue: hexonic.com/brazed-plate-exchangers/R

Frequently asked questions

Is this model suitable for R32 refrigerant?

Yes. R32 working pressure (high side ~35-40 bar) fits within 45 bar PN. R410A also works. R454B, R452B, R1234ze, R290 (propane) — also suitable (per the manufacturer catalogue). R744 (CO₂) — not suitable (max refrigerant-side pressure 45 bar).

Condenser or evaporator?

In condenser configuration, hot refrigerant vapour enters the top connection and condenses flowing downward. In evaporator configuration, two-phase refrigerant is fed from the bottom and evaporates flowing upward. The exchanger is physically the same — mounting orientation and piping arrangement are what matter.

What maintenance is required?

Brazed construction requires no disassembly maintenance. Water side — CIP flushing periodically. Refrigerant side — no maintenance needed (closed cycle).

Is insulation needed?

For R-type exchangers Hexonic offers RNI cold insulation (self-adhesive elastomer foam, -40…+110 °C, 20 mm) — recommended for the evaporator to prevent condensation and frost. APFI insulation is intended for the L series.