Hexonic RHB60-50H brazed plate heat exchanger for heat pumps, 50 plates

Hexonic RHB60-50H brazed plate heat exchanger for heat pumps, 50 plates

€ 1040,00+ PVM
SKU
0246-0193
Model
RHB60-50H
Delivery
1 - 2 working days.
Brand
Hexonic
used_for
silumokaitis_sildymui
Connection Type
2_x_iorsriegis_dn25__2_x_lituojamas_id_224_mm
Number Of Plates
50
Connection nozzles
4
degrees
1
product_analogue
cbh6050hf
Weight
15.6kg.
Have questions?
TL;DR: Hexonic RHB60-50H — brazed plate heat exchanger for heat pumps. Designed for refrigerant (condenser or evaporator duty) and water/glycol on the second side. 50 stainless steel AISI 316L plates, copper brazing. PN 45 bar refrigerant side, PN 25 bar water side.
  • Application: heat pump — refrigerant ↔ water/glycol (condenser, evaporator)
  • Heat capacity: ~100-250 kW (depending on refrigerant and mode)
  • Nominal pressure: 45 bar refrigerant / 25 bar water
  • Connection: welded connections on refrigerant side, threaded on water side

Where RHB60-50H is used

The RHB series (Refrigerant, B60 size, H profile) is designed to separate heat pump primary and secondary loops: one side — refrigerant (R32, R410A, R454B, R290, etc.), the other — water or glycol. Used as a condenser (heating mode) or evaporator (cooling mode). The RDS (Refrigerant Distribution System) special channel pattern ensures uniform refrigerant distribution and stable superheat.

Technical specifications

ParameterValue
Code0246-0193
SeriesHexonic RHB60 (R-line)
ModelRHB60-50H
Number of plates50
Plate profileH (higher chevron angle)
Nominal pressure — refrigerant side45 bar (4.5 MPa)
Nominal pressure — water side25 bar (2.5 MPa)
Max working temperature150 °C
Min working temperature-195 °C
Connection (refrigerant)Welded connection
Connection (water/glycol)G 5/4" or G 2" (depending on variant)
Plate materialStainless steel AISI 316L (1.4404)
Brazing fillerCopper (Cu)
Plate dimensions538 × 113 mm
Unit depth (F)~127.5 mm
Weight~15.6 kg
Media (refrigerant)R32, R410A, R454B, R1234yf, R290, R744 (CO₂ — consult on PN)
Media (secondary side)Water, glycol solutions up to 50 %

Heat pump sizing guidelines

Heat pump exchanger size depends on refrigerant type, evaporation/condensation temperatures and COP. General principle: condensers need larger area (smaller ΔT between refrigerant and water); evaporators need higher Δp tolerance due to two-phase flow.

Model RHB60-50H is suitable for heat pumps with ~100-250 kW heating capacity. Exact sizing must be verified via Hexonic CAIRO Selection Software or manufacturer calculation based on your compressor specifications.

Designer note: RDS (Refrigerant Distribution System) plates — for evaporator duty only. Condensers should use H profile without RDS. Before purchasing, confirm which function (evaporator / condenser) you need RHB60-50H for — we will verify the fit for your project.

When to choose RHB60-50H

  • Heat pump condenser with ~100-250 kW heating capacity
  • Heat pump evaporator with matched RDS pattern
  • When refrigerant working pressure is up to 45 bar (not for CO₂ transcritical — needs a special model)
  • When a compact solution with leak-tight welded refrigerant connections is required

When to choose an alternative

  • CO₂ (R744) transcritical cycle — needs PN 120 bar+ model (RHB60 not suitable)
  • Ammonia (R717) — needs nickel brazing (copper incompatible with NH₃)
  • Very large capacity (>500 kW) — larger series (RHC110, RHM110, cascade)

B2B delivery and logistics via Amegata.lt

  • 24-hour delivery across Lithuania (from our warehouse in Vilnius)
  • Competitive B2B pricing — often below market average
  • 30-day payment terms for companies (per contract)
  • Free technical consultation for heat pump exchanger selection

Official Hexonic catalogue: hexonic.com/brazed-plate-exchangers/R

Frequently asked questions

Is this model suitable for R32 refrigerant?

Yes. R32 working pressure (high side ~35-40 bar) fits within 45 bar PN. R410A also works. R454B, R1234yf, R290 (propane) — also suitable. R744 (CO₂) — not suitable, needs a special 120 bar+ model.

Condenser or evaporator?

In condenser configuration, hot refrigerant vapour enters the top connection and condenses flowing downward. In evaporator configuration, two-phase refrigerant is fed from the bottom and evaporates flowing upward. The exchanger is physically the same — mounting orientation and piping arrangement are what matter.

What maintenance is required?

Brazed construction requires no disassembly maintenance. Water side — CIP flushing every 3-5 years. Refrigerant side — no maintenance needed (closed cycle).

Can ammonia (R717) be used?

No. Ammonia chemically reacts with copper and will damage the brazing filler. R717 systems require a nickel-brazed model or an all-stainless variant (Hexonic Luna R-series).

Is insulation needed?

For heat pump condenser — hot-side insulation is recommended (APFI series). For evaporator — cold-side insulation (special type down to -40 °C, 20 mm thickness) is essential to prevent condensation and frost.